Description
Features of Pulse Oximeter Atom AT-975 Blood Oxygen Saturation and pulse rate monitor
- Pulse oximeter Atom designed for everyone’s health with accurate and easy reading.
- Large front screen display
- Four directional display
- Double layer anti skid pad made of silicon is more comfort to measuring
- 3 level brightness
- Auto Alarm
- One button operation
- Rapid measurement
- Highly accurate
- Portable and easy to carry
Precautions for use of Pulse Oximeter Atom
- Do not use the pulse oximeter together with MRI or CT equipment.
- Explosion hazard: Do not use the pulse oximeter in an explosive atmosphere.
- The pulse oximeter is intended only as an adjunct in patient assessment. Doctors should make diagnosis in conjunction with clinical manifestation and symptoms
- Check the pulse oximeter sensor application site frequently to make sure that the circulation and skin Integrality of patient are under good condition.
- Do not stretch the adhesive tape while applying the pulse oximeter sensor. This may cause inaccurate reading or skin blisters.
- Please read the manual carefully before your operation.
- The pulse oximeter has no SpO2 prompt, it is not for continuous monitoring.
- Prolonged use or the patient’s condition may require changing the sensor site periodically. Change sensor site and check skin integrality circulatory status, and correct alignment at least every 2 hours.
- Inaccurate measurements may be caused by autoclaving, ethylene oxide sterilizing, or immersing the sensors in liquid.
- Significant levels of dysfunctional hemoglobins (such as carboxyl- hemoglobin or methemoglobin) may cause inaccurate reading.
- Intravascular dyes such as indocyanine green or methylene blue may cause inaccurate reading.
- SpO2 measurements may be adversely affected in the presence of high ambient light. Please shield the sensor area (with a surgical towel or direct sunlight, for example) if it is necessary.
- Unexpected action may cause inaccurate reading.
- Medical signal with high frequency or interference caused by defibrillator may lead to inaccurate reading.
- Venous pulsations may cause Inaccurate reading.
- It may cause inaccurate reading when the positions of sensor and blood pressure cuff are on the same arterial catheter or intravascular line.
- Hypotension, severe vasoconstriction, severe anemia, or hypothermia may cause inaccurate reading.
- It may cause inaccurate reading by giving use of cardiotonic to patient after his cardiac arrest or when he is in quiver.
- Bright nail or painted nail may cause inaccurate SpO2 reading.
Specifications of Pulse Oximeter Atom AT-975
Properties | Details |
---|---|
Display Type: | OLED display |
SpO2: | Measurement range: 70%-99% |
Accuracy: 2% on the stage of 80%-99 13% (when SpO2 value is 70% -79%) | |
Below 70% no requirement | |
Resolution: 1% | |
PR: | Measurement range: 30BPM-240BPM Accuracy: 1BPM or 1% (the larger one) |
Pl index: | measurement scope: 0-20 (optional) |
Power: | two AAA 1.5V alkaline batteries |
Power consumption: | below 30mA |
Automatic power-off: | the product turns off by itself when no finger is in the product |
Automatic startup: | every 5 s Instrument will automatically detect the signal |
Accelerometer function: | finger movement, the screen display will change with the accelerometer changes |
Dimension: | 58mmx36mm*33mm |
Operation Environment: | Operation Temperature: 5C-40 C |
Storage Temperature: -10 C-40 C Ambient Humidity: | |
15%-80% on operation 10%-80% in storage | |
Air Pressure: 86kPa-106kPa |